Automatic Servo Voltage Stabilizer/AVR

BWSVC Series ( 1KVA ~ 100KVA )

For Applications

  • CNC/Medical equipment
  • Electrical Discharge Machining
  • Plastic Injection Machine
  • PCB Drilling Machine
  • Printing Press
  • Embroidery equipment
  •  
Frequency Converter

Main Features

  • Wide range of permissible input
    voltage windows (±20% to ±40%)
  • Automatic delay output, when the
    AVR Start Up,it will not output
    untill the voltage has been
    stabilized to protect the loads
    from damage.

Blue Whale BWSVC series Servo Voltage Stabilizer is designed to regulate voltage automatically – that is to take a fluctuating voltage level and turn it into a constant voltage level.

“It will also keep the output voltage stable during peak loads, thus helping CNC/PLC/Medical/
Laser/Printing equipment and other voltage-sensitive equipment to operate properly.”

“Inbuilt protection also ensures that the load is continuously protected against harmful mains born high energy surges, spikes and transients.
Intended for indoor use only in dry locations, but can be placed in a rain tight enclosure for use in wet or damp locations.”

Technical Specification

 

Capacity

1kVA ~ 100kVA (Select One specific kVA)
Single phase:1/2/3/5/8/10/15/20/30/45/60kVAThree phase:6/10/15/20/30/40/50/60/80/100kVA

Input  
Single phase 220V ±20%(176V~ 264V) -Standard Type
Or 120V±20%(96V~ 144V)-Optional
Or 220V ±40%(132V~ 308V) -Optional
Three phase 380V ±20%(304V~ 456V) -Standard Type
Or 220V±20%(176V~ 264V)-Optional
Or 380V ±40%(228V~ 532V) -Optional
Frequency 50Hz/60Hz
Output  
Single phase 220V±2% Or 120V±2%
Three phase 380V±2% Or 220V±2%
Frequency 50Hz/60Hz
Voltage Accuracy ±2%
Efficiency 98%
Distortion Do not produce additional waveform  distortion
Response Time 500ms
Overload 80% continuous,Capable for Peak Current by  Inductive Load
Protection

Over current:Electronic detection and circuit  breaker dual protection
Over voltage:Output phase voltage is higher  than 10℅,cut off the output automatically
Under Voltage:output phase voltage is lower  than 10℅,cut off the output automatically
Short circuit:Electronic detection and circuit  breaker dual protection

Enclosure IP IP22 Standard Type
IP54 Optional
Display Input voltage and output voltage
Working condition  
Temperature Operation: -10℃~45℃
Noise ≤ 65dB at 1 meter
Humidity 10~90% non-condensing
Insulation Resistance Coil VS ground ≥ 100MΩ
Cooling System Air Cooling/Exhaust Fan
Connection Type Terminal Block
Ground Resistance ≤ 0.1Ω
Insulation Voltage Coil Vs conductor 250V 60S(≤ 10mA)
Standards GB 50054-95                 
GB 50150-1991GB 50150-2006           
GB 50171-1992GBT 5465.2-2008         
GB/T 16935.5-2008       
GB/T 16935.4-2011